Earthquake IG800W Model 11613 Portable 800-Watt Inverter Generator

Earthquake IG800W Model 11613 Portable 800-Watt Inverter Generator with 40cc 4-Cycle OHV Viper Engine (CARB Compliant)



I four days after the end of Wisconsin. It comes with a manual screwdriver tool candle and a charging cable to the 12-volt battery. I noticed only a loose screw, screw the pole soil by removing the screws on the front panel, access is easy to be attracted. The oil filling in a side wall is held by four screws. It would be easier if it ensures with screw cap, as the oil level should be checked before each use. I had to use the air filter with oil in preparation. Be careful with respect to the sale of auction: it seems easy to be a cross wire.

After filling with 10W-30 oil, using a small funnel with the help of 350 cc for instructions, I filled the container with about half a liter of gasoline without octane rating of 89 Ethanol There is a large opening in the fuel filter. I turned the machine, fuel valve, open container, founded six times with the throttle, insert the starter and continued. The first shooting began (I was surprised), but before I could from the starter, then stop, then as soon as I turned and started running me held the second shot. Regarding hot start when you turn it off, then try to start immediately, you do not need the choke. After a few minutes, then you should start to trigger a cold start and suffocation. Later, I tried to start and it took maybe five or six times, and after about 3 or 4. The warm start, seemed to require priming, three draws with the choke on, and then I turned to stifle Start, Run.Until now I have to walk about 10 minutes, with and without load of 200 watt bulb.

ECON switch has a minor influence on the minimum and also noise. The ramps of the load function generator. Unlike incandescent bulbs, I also tried to practice the variable speed of 350 watts, and the generator has no problems with the management of it, and it is still very quiet at this power level. Once I broke a few hours I will see how he accepts much closer evaluation.

It is a very quiet generator, measured at about 58-59 dBA on concrete, with my burden light 200 watts, with my iPad application, compared to about 68 dBA for my Harbor Freight Storm Cat, and about 72 DBA (with the same application) for my two biggest producers, a Champion 3500/4000 Watt Generator and my main house, a Honda EM6500SX. The sample is a little behind for my backup. The numbers do not really tell you how 59 dBA quiet. 10 dBA is a lot of noise. Without load the grass ECON setting, the generator spin at about 56 dBA in the iPad application. That's impressive for a generator for such a declaration. I do not have a Honda EU for direct comparison, I think the specifications of the EU1000i are 53 dB (A) at 1/4 load 59 dB (A) at nominal load, so it should be a little " quieter than its where the quake.

Storm Cat Harbor Freight is cheap, but for the fact that only 100 watts more is much heavier at 37 pounds, and compared to the earthquake that weighs only 21 pounds relatively strong. I think the earthquake is a great value. I want a Honda EU1000i, but the additional cost of $ 500 for this lot of earthquakes. You get more by paying more more power, less noise, Honda reliability, parallel power, more sales ... but it's worth the money three times? As regards the long-term durability, service and quality of the production for my earthquakes, they have no answers. As IG800W inverter accepts a pure sine wave and probably safe for electronics. I take my cat tower is not at all sensitive, under varying loads saw relatively large fluctuations in voltage and frequency.

This generator is a good choice, light power fuel consumption, low noise laptop which would be appreciated.

Updated 20 hours of operation: This generator is good, do not be a problem. It is always easy to start, go to 1-2 times after filling. At this point I changed the oil when the List Manual. Will do the same, all races to 769 watts measured on a Kill-a-Watt, a little weak "short for RPM faster recovery and tension. No increase in performance at any time, with a fixed frequency of 60 Hz . I really believe is good and remains to this day. Only 5 stars ...

I have some videos on YouTube of this generator. Seek and you will find three sub IG800W m60mgman ...

Ok, I have this time with some devices: Here are my results: Freight Port 4.5 ": 4.5 A (540 watts) mill is fine, no problem.

I tried a circular saw Craftsman Kill A Watt says is about 830 watts online: surprisingly generator keeps trucking. I do not really cut each 2-by-4s with it: it runs on 839 watts, downloaded, so cuts would probably be enough to trigger the switch. If they say 800 watts means ...

If I. A circular saw with what I would do small generator in the range of 700 watts, and use it with care to avoid the stagnation of the saw
 Earthquake IG800W Model 11613 Portable 800-Watt Inverter

Haier 6000 BTU air conditioner (5.5 Amp Energy Star units) generator stops immediately if it starts to cool, or if you turn the fan on and on. I had no problems playing these A / C units with cargo generator port. The additional 100 watts seems to make a difference.

We need someone to monitor a unit 5000 BTU A / C, if it works with this generator ...